How VERA™ assesses your quality system and design history files, how to read your results, and how your data is protected. Can't find your answer? Contact us.

Getting to know VERA™

What is VERA™?

VERA™ is a multi-tenant SaaS platform from Warwick Consulting, built for medical device manufacturers. It reads your quality system and design documents against the regulations and standards that apply to your products, and shows you, requirement by requirement, where you stand.

Every finding quotes the passage it relied on and explains its reasoning, so your team can see exactly why VERA™ reached it. Each manufacturer's workspace is private and isolated. Your documents, results and decisions are never visible to another company.

What can VERA™ assess?

Two things. A QMS assessment reviews your quality manual, procedures, work instructions and forms against the regulations and standards in your scope. A DHF assessment reviews a product's design history file: whether each design phase is complete, whether requirements trace through to verification and validation, whether your documents agree with each other, and whether the design conforms to the standards that apply to the device.

How it works

How does a QMS assessment work?
  1. You upload your QMS documents.
  2. VERA™ breaks every regulation and standard in your scope into its individual requirements.
  3. For each requirement, it searches your documents for the passages that bear on it.
  4. A large language model reads those passages against the requirement and decides whether it is addressed, partly met or a gap, writing down its reasoning and quoting the text it used.
  5. Your reviewers check each finding and sign a decision.

Each assessment reads only your documents and the regulatory text. Nothing from another company's assessment is involved.

How does a DHF assessment work?
  1. You answer a short intake about the device, covering its type, class, markets and features such as software, wireless connectivity or sterility. VERA™ uses your answers to decide which standards apply and records the reasoning in an applicability document you can download.
  2. VERA™ reads your design control procedure to learn your development phases and what each phase gate requires.
  3. You upload the design history file: plans, requirements, specifications, drawings, risk files, and verification and validation records.
  4. VERA™ checks each phase gate, traces requirements through to verification and validation, reviews every document and drawing, compares documents against each other for conflicting values, and checks the design against each applicable standard clause by clause.
  5. You get a single register of findings with an overall conclusion, which your reviewers check and sign.
Which regulations and standards does VERA™ cover?

VERA™ works from the full text of the regulations themselves. Its library holds 43 regulatory instruments across the six major medical device markets: the United States, the European Union, Canada, Japan, Australia and Brazil. In the US that includes the QMSR in 21 CFR Part 820 and the parts that govern electronic records, labeling, adverse-event reporting, registration, tracking, corrections and UDI. In Europe it includes the MDR and IVDR with their quality system annexes, and it covers Health Canada's Medical Devices Regulations and Japan's PMD Act and QMS ordinance.

Alongside the regulations sit the international standards for quality, risk and usability, such as ISO 13485, ISO 14971 and IEC 62366-1. Your company can add the product standards it holds, for example for electrical safety or software, and VERA™ assesses against those as well.

Requirements are mapped across markets, so a finding against a US requirement also shows what it means in the EU, Canada or Japan. VERA™ also draws on FDA enforcement and clearance records, including warning letters, inspection observations, recalls and 510(k), De Novo and PMA decisions, to show which requirements regulators are acting on.

Your company profile sets the scope of a QMS assessment, and the device intake sets the scope of a DHF assessment. You can browse the full library under Standards & Regulations.

Which AI models does VERA™ use?

Large language models from AI providers we have contracts with read your documents and judge each requirement. A separate search model finds the relevant passages. Every provider is named in the privacy notice, and each QMS assessment records which model it used.

How long does an assessment take?

A QMS assessment against US FDA regulations and ISO standards typically finishes within an hour. A DHF assessment depends on the size of the file and the number of standards that apply. You can follow progress on the QMS assessments and DHF assessments pages.

Reading your results

What do Gap, Partial and Addressed mean?
  • Gap: none of your documents address the requirement. A procedure or record needs to be written.
  • Partial: your documents cover some of the requirement, but at least one element or condition is missing or unclear.
  • Addressed: your documents cover every element of the requirement.

Requirements that don't apply to your products are set aside as out of scope and aren't counted.

What do the DHF conclusions mean?
  • Adequate: everything checked is addressed.
  • Attention Required: there are no gaps, but some items are only partly met or couldn't be assessed.
  • Remediation Required: at least one gap, none of them critical.
  • Not Ready for Closure: at least one critical gap.
Is a VERA™ result a regulatory determination?

No. VERA™ reviews your documents. It doesn't inspect your facility, interview your staff or observe how procedures are followed in practice, and it doesn't predict the outcome of an audit. Your team reviews and signs every finding, and the conclusions are yours.

How are findings reviewed and signed?

A reviewer checks the finding, records a decision with a rationale, and signs. An approver then countersigns, and the decision becomes final. VERA™ stamps each signature with the date and time, and signatures can't be edited or deleted. To change a decision, someone signs a new one, and both stay on the record.

What does Defer do?

Defer takes a finding out of the review queue for now. It comes back in the next assessment, so nothing is lost.

Does VERA™ learn from our decisions?

VERA™ remembers the final, two-signature decisions your company has made and shows them as precedent when the same requirement comes up again. It doesn't retrain the AI models on your decisions or your documents, and one company's decisions are never shown to another.

Accuracy and validation

How does VERA™ keep its findings accurate?

Every finding names the requirement, quotes the passage from your documents it relied on, and explains its reasoning in plain language. Before a finding is kept, VERA™ checks each quote word for word against your source document, so it can't cite text your documents don't contain.

What if a requirement is covered across several documents?

VERA™ reads every procedure that bears on a requirement, not only the one you might expect. If a requirement is met in another SOP, or partly in one and partly in another, it gets credit for that. You won't be asked to fix something your QMS already handles.

How is VERA™ validated?

VERA™ is validated as a computerized system used in a regulated setting, following GAMP 5 as a Category 4/5 system: a configured SaaS platform with a custom AI layer. Its validation covers user and functional requirements, design specification, a risk-based assessment, installation, operational and performance qualification, and a traceability matrix that links every requirement to the test that proves it.

Accuracy is measured against reference quality systems and design history files seeded with known gaps, where the right answer is fixed in advance, by counting the gaps VERA™ finds and any it raises in error. More than 2,500 automated tests check the platform itself.

The platform is built to the control baselines of SOC 2 Type II and ISO/IEC 27001, covering access control, encryption, change management, and logging and monitoring. Its AI governance is built to ISO/IEC 42001, with ISO/IEC 23894, BS 30440 and the EU AI Act as references: a person reviews and signs every finding, every finding shows its evidence and reasoning, and every decision is logged. Electronic records and signatures are designed to meet 21 CFR Part 11.

What happens when a regulation or standard changes?

The library is updated with the new text. Run a new assessment to see how the change affects your QMS or design file. Your earlier results stay as they were, so you can compare the two.

Security and privacy

Who can see our documents?

The people in your company you give access to, and the Warwick Consulting team supporting your assessments. Each company's documents and results are kept separate from every other company's.

Where is our data stored?

In AWS data centers in the United States. Your data is encrypted at rest and in transit.

Are our documents used to train AI models?

No. Your documents go to the AI providers only to produce your results, under terms that don't allow them to be used for training.

How is VERA™ secured?

Every sign-in uses multi-factor authentication, and each person's role sets what they can see and do. Each company's data sits in its own isolated space, and the platform runs behind a web application firewall with continuous automated security scanning.

Is there an audit trail?

Yes. Sign-ins, uploads, assessments, signed decisions, exports and changes to user access are recorded with who did what and when. No one, including administrators, can edit or delete that record.

Using VERA™

What files can I upload?

PDF, Word, Excel and PowerPoint files (.pdf, .docx, .doc, .xlsx, .pptx), one at a time or together in a ZIP file. VERA™ reads your Excel registers, logs and forms and your PowerPoint training material along with the rest of the QMS, and a DHF can include a trace matrix or risk file kept as a workbook. In a workbook or presentation, VERA™ reads the text and tables and skips pictures and charts. Older .xls and .ppt files can't be opened, so save them as .xlsx or .pptx first.

How do I add people from my company?

Your company admin invites them from Team & Access and chooses what each person can see and do.

Why was I signed out?

For your security, VERA™ signs you out after 30 minutes without activity. A warning appears two minutes before, so you can stay signed in.

How do I get help?